CoaguCheck XS
Tap on the gear wheel to show the settings and tap on the heart icon to change values.
CoaguCheck Keypad
Once you enter the desired INR value to be shown, tap on Confirm.
The tap on Hide Settings and hand the device to the student.
Student use of simulated CoaguCheck
For reference, tap on the ? icon to show simulation instructions
Hand the device to the student
Tap power button to power on.
Once the device has powered on, the test strip indicator will flash.
Tap where the test strip is entered into the device to add a test strip.
Once the test strip has been added, the code chip number is shown.
The student should compare this number to the code-chip number on the test strip bottle and then press M.
This will then start the countdown from 180 seconds.
Tap on the test strip again. The test strip window becomes red and the countdown will stop.
QC (Quality Control) is then shown.
Finally the result is displayed